Each kit contains No.5 doseBadges with all the necessary components for an occupational noise assessment system.
Includes:
- Individual doseBadges
- Reader Unit
- Charger & Power Supply
- Cables
- Software
- User Manuals
- Robust aluminium transport case
Read more...
The doseBadge is the original wireless personal noise dosimeter. It is the ideal tool to carry out occupational and industrial hygiene noise measurements and provides a unique solution for these applications.
Combining an innovative design with simple, robust and reliable operation, the doseBadge weighs only 51g/1.8oz.
With no cables, controls or displays, the doseBadge can be worn in areas where there is a risk of damaging traditional style units or where there is a risk of tampering.
It’s an innovative instrument that is ideal for measuring and assessing the noise exposure of workers and employees across all locations.
The doseBadge is a dual channel instrument that will measure, store and calculate the parameters essential for compliance with occupational noise regulations.
These include LAeq, LCPeak & LEP,d as well as % Dose, LAVG & TWA. Along with these overall values, the doseBadge will store a Time History, or Noise Profile, throughout the measurement, for both channels.
The doseBadge survives in the toughest environments
The doseBadge has been designed to survive use in the toughest and harshest environments. There are no cables, controls or displays to damage and the microphone, battery and electronics are all housed in a robust and lightweight metal case which is strong enough to withstand being dropped, knocked or even stood on.
The robust metal case protects the internal systems and microphone of the doseBadge. By locating the microphone inside the case, the doseBadge is completely self contained and will give many years of reliable operation.
Applications for the doseBadge Noise Dosemeter
Due to its unique and robust design, the doseBadge is used across a wide range of different applications where there is a need to carry out assessments of the noise exposure of workers. Below are some examples:
- The measurement and control of occupational noise exposure.
- Compliance with Noise at Work Regulations, Industrial Hygiene Standards and Occupational Noise Exposure Guidelines.
- Monitoring and recording of long term noise exposure.
- Noise exposure measurements in Hazardous environments such as Oil Refineries, Petrochemical Plants and Underground Mines.
- Measurement of noise exposure in the Entertainment and Music Industries.
Create measurement reports quickly and simply
The NoiseTools software is supplied with the doseBadge and this software has been designed to be simple to use and give you the information you really need without being complicated or complex.
Simply download your measurements and create reports quickly and easily with simple or comprehensive options available.
NoiseTools is supplied free from any licencing restrictions and can be installed onto as many PC's as needed without having to purchase additional copies.
Updates for NoiseTools are available free of charge from the Cirrus website.
doseBadge Measurement Kits
We can supply up to 10 doseBadges in a single kit which contains the doseBadges along with a Reader Unit, Chargers, Power Supply, Mounting Kits, Software, User Manuals, USB Cable and Batteries for the Reader Unit.
Features
- Robust aluminum case protects the equipment during transport & storage
- Contains all of the components of the doseBadge system
- Individual doseBadges
- Reader Unit
- Charger & Power Supply
- Cables
- Software
- User Manuals
Specifications*
Applicable Standards
IEC 61252:1993 Personal Sound Exposure Meters
ANSI S1.25:1991 Personal Noise Dosemeters Class Designation
2AS-90/80-5
RC:110A: Internal Acoustic Calibrator to IEC 60942:2003 Class 2
Measurement Range (Typical)
70dB(A) to 130dB(A) RMS, 120dB(C) to 140dB(C) Peak
Measurement Functions
Overall Measurement Data
doseBadge Configuration (Badge Serial Number, Date & Time)
Calibration Record
Measurement Duration
Highest Peak(C) Sound Level during the measurement
Overload Exceedence
115dB(A) Maximum Sound Level Exceedence
Battery Status
LAeq, LEX,8h, LAE, % Dose, Exposure (Pa2h)
Estimated % Dose, Estimated Exposure (Pa2h)
1 Minute Time History of:
LAeq, Peak(C) Level & Battery Level
Frequency Weightings
‘A’ for all RMS measurements
‘C’ for Peak Sound Pressure
Configuration Options
Channel 1: Independent User Configuration of:
Exchange Rate: 3dB, 4dB or 5dB
Criterion Level: 80dB, 85dB, 90dB
Criterion Time: 8hrs, 12hrs, 16hrs, 18hrs
Threshold: None, 80dB, 90dB
Time Weighting: None, ‘S’ (Slow)
Channel 2: Preset to
Exchange Rate:3dB
Criterion Level: 85dB
Criterion Time: 8hrs
Threshold: None
Time Weighting: None
Memory
CR:110A doseBadge
The CR:110A doseBadge can store up to 24 hours of data in a
single measurement
RC:110A Reader
Up to 999 Individual doseBadge Measurements
Power
RC:110A doseBadge
Internal NiMH Battery. Typical Battery Life 30 hours @ 80dB
RC:110A Reader
2 x AA/LR6 with Auto Power Switch Off
CU Series Chargers
CU:195A Mains Power Supply. Fast Charge Option
Output
CR:110A doseBadge
Wireless Infrared to RC:110A Reader Unit
RC:110A Reader
USB 2.0 (which also provides power to the RC:110A Reader)
Dimensions
CR:110A doseBadge
Microphone Apex Ø13.0mm, Base Ø47mm, Height 38mm
Weight
CR:110A doseBadge 51g (1.8oz)
RC:110A Reader 400g (14oz)
Temperature
-10°C to +50°C Operating
-20°C to +60°C Storage
Humidity
Up to 95% RH Non-Condensing
Software
NoiseTools software supplied as standard with license free
installation and free of charge upgrades available from the
Cirrus website
* The specifications shown in this datasheet are a summary of
the overall specifications for the doseBadge Noise Dosemeter.
Full details are available on request or from the Cirrus website.